TECHNICAL SPECIFICATION
| INPUT |
|
|
| |
Voltage |
230 - 120Vac ± 20%,1- Phase |
| Frequency |
50 - 60Hz ± 6%
|
| Güç Faktörü
|
0,95
|
| OUTPUT |
|
|
| |
Voltage |
48 / 63 / 75 / 87 Vac
|
| Current |
4 / 8 / 12 / 16A
|
| Power |
200 – 1400VA
|
| Ripple
|
< 1%
|
| Voltage Regulation |
± 3%
|
| Efficiency |
> 92%
|
| Protection |
Overload and Short-circuit |
| GENERAL |
|
|
| |
Galvanic Isolation |
4 kV
|
| Insulation Class |
F
|
| Protection Class |
IP 20
|
| Safety |
CE marked |
| ENVIRONMENTAL |
|
|
| |
Operating Temperature |
-10 ºC ... +55ºC |
| Relative Humidity |
0 – 90% (Non-condensing) |
| Audible Noise (10-100% load) |
< 45 dBA @ 1m.
|
| MECHANICAL |
|
|
| |
Dimensions (WxDxH) mm |
WM1 1: 235x190x210 WM2: 260x190x260 |
| Net Weight (WM2, 750VA) |
17,6 kg |
All specifications are subject to change without prior notice. WM1
is the small wallmount enclosure intended for space-critical applications.
No panel meters and only two coaxial connectors are availabe with
this type of enclosure. WM2 is the large wallmount enclosure which
allows up to two panel meters and four coaxial connectors. Add 40mm
to width and 15mm to depth for mounting straps.
*If coaxial output connectors are preferred then only a single standard
output channel will be provided.
|
 |
|
|
 |